Hyundai Elantra: Heater / Auto Defoging Actuator Specifications

Specifications
Door position
Voltage (V)
Error detecting
Max. cooling
0.3 ± 0.15
Low voltage : 0.1V or less
Max. heating
4.7 ± 0.15
High voltage : 4.9V or more

Auto Defoging Actuator Description and Operation
Description The auto defogging sensor is installed on front window glass. The sensor judges and sends signal if moisture occurs to blow out wind for defogging. The air conditioner control modul ...

Auto Defoging Actuator Repair procedures
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the auto defogging connector. 3. Verify that the auto defogging actuator operates to the open position when connecting 12V to ...

Other information:

Hyundai Elantra AD (2016-2020) Service Manual: Troubleshooting
Troubleshooting     • The battery must be in good condition and fully charged for this troubleshooting. ...

Hyundai Elantra AD (2016-2020) Service Manual: Ambient Temperature Sensor Description and Operation
Description The ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature. The sensor output will be used for discharge tem ...