Hyundai Elantra: General Information / Special Service Tools

Special Service Tools
Tool (Number and Name)
Illustration
Use
Deployment tool
0957A-34100A

Airbag deployment tool.
Use with (0957A-AL140, 0957A-AL150, 0957A-AL160)
Dummy
0957A-38200

Simulator to check the resistanceof each wiring harness.
Use with (0957A-AL170, 0957A-AL180, 0957A-AL190)
Airbag deployment & dummy adapter kit
0957A-AL100

Use with airbag deployment and airbag inspection
Deployment adapter
0957A-AL140

Use with deployment tool. (0957A-34100A)
(DAB, PAB, CAB, BPT, EFD)
Deployment adapter
0957A-AL150

Use with deployment tool. (0957A-34100A)
(KAB)
Deployment adapter
0957A-AL160

Use with deployment tool. (0957A-34100A)
(SAB)
Dummy adapter
0957A-AL170

Use with dummy (0957A-38200)
(DAB, PAB, CAB, BPT, EFD)
Dummy adapter
0957A-AL180

Use with dummy (0957A-38200)
(KAB)
Dummy adapter
0957A-AL190

Use with dummy (0957A-38200)
(SAB)

DAB : Driver Airbag
PAB : Passenger Airbag
SAB : Side Airbag
CAB : Curtain Airbag
KAB : Knee Air Bag
BPT : Seat Belt Pretensioner
EFD : Emergensy Fastening Devise
Specifications
Specification ItemResistance (?)Driver Airbag (DAB)1.7 ~ 6.0Passenger Airbag (PAB)1.7 ~ 6.0Knee Airbag (KAB)1.7 ~ 6.0Side Airbag (SAB)1.8 ~ 6.0Curtain Airbag (CAB)1.7 ~ 6.0Seat Belt Pretensioner ...

General Safety Information and Caution
Precautions General Precautions Please read the following precautions carefully before performing the airbag system service. Observe the instructions described in this manual, or the airbags cou ...

Other information:

Hyundai Elantra AD (2016-2020) Service Manual: Rear Center Seat Belt Retractor Repair procedures
Replacement     • When installing the belt, make sure not to damage the retractor. 1. Remove the package tray trim. (Refer to Interior Trim - "Rear Package Tray Trim") 2. After loosening the mounting bolts, remove the rear center seat belt retractor (A). Tight ...

Hyundai Elantra AD (2016-2020) Service Manual: Ambient Temperature Sensor Description and Operation
Description The ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature. The sensor output will be used for discharge tem ...

© 2018-2025 www.helantraad.com